| Environmental | ||
| Formaldehyde Emission(In air) | EN 14041:2004 | Pass – ≤0.08mg/m³ | 
| ASTM D6007-14 | ND – Not Detected | |
| Phthalates Content | EN 14372: 2004 | ND – Not Detected | 
| Migration of certain elements | EN71-3:2013+A1:2014 | ND – Not Detected | 
| Formaldehyde Acetaldehyde TVOC | Floor Score Indoor Air Quality | Pass – 3.69ug/m2-h | 
| SCS-FS-06767 | Pass – 2.69ug/m2-h | |
| Pass – 178.6ug/m2-h | ||
| Testing | ||
| Dimensional Stability | Transverse – 80℃ | Pass – 0.01% | 
| Longitudinal – 80℃ | Pass – 0.04% | |
| Curling | Pass – 0.01mm | |
| Residual Indentation | ASTM F1914 | Pass – Avg ≤ 1.0%,Max 1.2% | 
| Peel Resistance | EN ISO 24345:2012 | Pass – 145N/5cm | 
| Impact Insulation Class (IIC ) | ASTM E492-09 / ASTM E989-06 | 57dB | 
| Sound Transmission Class (STC) | ASTM E90-09 / ASTM E413-16 | 51dB | 
| Reaction To Fire | EN 13501-1:2007 | Bfl-s1 | 
| Critical Flux | EN ISO 9239-1 | ≥ 11.1kW/m² | 
| Smoke | 139.1%×minutes | |
| Abrasion Resistance | EN660-2:1999 & EN649:2011 | 1.4mm³/100 Revolutions | 
| Wear Group T | ||
| Castor Chair Test | EN 425:2002 | Pass – No Damage | 
| Locking Strength | Unclick System | Pass – 262 & 269 N/5cm | 
| Scratch Performance | Pass – 2800g | |
| Resistance To Chemicals | ASTM F925-13 | Pass – Not Affected | 
| Thermal Conductivity | EN 12667:2001 | Pass – 0.122 W/(m·K) | 
| Water Tightness | EN 13553:2017 | Pass – No Sign | 
| Dynamic Coefficient of Friction | EN 13893:2002 | Pass – Class DS | 
 
								 
								 
																								